Dual-chamber freezers with inverter-controlled compressors

Product image: Axofreeze -86°C Ultra-Low Temperature Freezer MF-86V838TDV, 838 l, Energy-Saving Model with Touchscreen
Back to overview
Item no. 40735

Axofreeze -86°C Ultra-Low Temperature Freezer MF-86V838TDV, 838 l, Energy-Saving Model with Touchscreen

Capacity 600 boxes, 60,000 samples, Power consumption 7.9 kWh/day at -75°C

List price
€ 13.900,00

Product information

Axofreeze MF-86V838TDV: Maximum Sample Safety Through Redundant Cooling

The Axofreeze MF-86V838TDV offers 838 liters of capacity, providing space for up to 60,000 samples. The innovative redundant dual cooling system ensures consistent storage at -80°C even in the event of a compressor failure. Thanks to VIP+ vacuum panels and frequency-controlled compressors, this model achieves outstanding energy efficiency of just 7.9 kWh/day with maximum quiet operation.

This highly efficient, energy-saving model is the ideal choice for biobanks, clinical laboratories, and the pharmaceutical industry. Discover professional laboratory solutions at axon-labortechnik.de and optimize your sample logistics. Request your no-obligation quote now!

Frequently Asked Questions About the Axofreeze MF-86V838TDV

How does the redundancy in the dual cooling system work?

The system operates with two completely independent cooling circuits, each equipped with its own compressor. In normal operation, both circuits share the load, which increases efficiency. Should one circuit fail, the second automatically takes over full cooling capacity and keeps the temperature stable at -80°C. This provides double protection for highly sensitive sample materials.

What advantages do the VIP+ insulation and HC refrigerants offer?

The 90 mm thick VIP+ vacuum insulation massively reduces heat ingress from outside compared to standard insulation, which lowers power consumption. Combined with natural hydrocarbon refrigerants (HC), a GWP value of zero is achieved. This protects the environment and makes operation of the ultra-low temperature freezer particularly sustainable. In addition, the warm-up time during a power outage is significantly extended.

How is complete documentation of storage conditions ensured?

Control is performed via a 10.1-inch touchscreen, which visualizes all relevant data and stores it via a USB interface for up to 10 years. An integrated battery maintains the display and alarm system for approximately 48 hours during a power outage. The device can also be integrated directly into a central laboratory monitoring network via the RS485 interface. Alarms are reported visually, acoustically, and via remote contact.

Technical data & description

Technical Data and Equipment Features: Dual cooling system with two independent refrigeration circuits In case of compressor failure, the second compressor alone maintains -80°C permanently. Frequency-controlled compressors enable particularly economical operation. Low power consumption of 7.9 kWh per day Temperature range -40°C to -86°C Maximum ambient temperature 32°C Refrigerant mixture based on hydrocarbons (HC gas), CFC-free, GWP = 0 Refrigerants R600a (isobutane), R1150 (ethylene) and R50 (methane) Low noise level of 50 dB(A) Four swivel castors with locking feet Two cable conduits with Ø 25 mm, one at the rear - one at the side, for external temperature sensors Lockable door handle made of sturdy aluminum die-casting External housing with baked-on lacquered sheet steel, internal housing stainless steel Front grille with magnetic bracket, easily removable for dust filter cleaning Housing insulation with vacuum panels (VIP+) foamed in polyurethane, thickness 90 mm Warm-up time from -80°C to -50°C approx. 4.5 hours Four-layer silicone gasket with heated sealing surface prevents ice formation Two insulated inner doors Heated, frost-free passage for vacuum relief Internal dimensions 885 x 720 x 1310 mm (W x D x H) External dimensions 1145 x 995 x 1980 mm (W x D x H) Removal of door and front panel enables passage through 90 cm wide doorways. Weight 325 kg Power supply 220-240 V/50 Hz Control and Alarm Functions: Microprocessor control with 10.1" LCD display, password-protected USB interface for reading temperature data over 10 years RS485 interface for network integration of multiple units Battery for maintaining display and alarm notifications during power failure Battery hold time approx. 48 hours Alarm notifications provided optically, acoustically and as remote alarm via potential-free contact for - Over- and under-temperature (alarm thresholds can be set individually) - Temperature sensor failure - Power failure - Battery weakness - Condenser over-temperature - Excessive ambient temperature Warranty: 12 months 36 months parts warranty Wear parts such as gaskets or batteries are excluded from warranty. Valid only for installation within Germany. Optional Accessories: Drawer racks for boxes of any size Cost-effective boxes made of polypropylene or water-resistant cardboard CO₂ backup system Alarm notifier for push notifications/calls/SMS/e-mail Unlock via fingerprint scanner or chip card Temperature recorder
Large product image