110 Liter Chamber Volume for High Sterilization Demands
The Steam Sterilizer HV-110L with 110 liters of chamber volume is suitable for laboratories with a high throughput of items to be sterilized. Thanks to the fully automatic microprocessor control and 12 preset programs, it is suitable for microbiology, biotechnology and pharmaceutical institutes where reliable steam sterilization is required.
The device offers a night program for overnight sterilization, an AGAR program with residual heat, as well as a liquid program with a 95°C removal temperature. The working temperature ranges from 105°C to 123°C at a max. chamber pressure of 1.2 bar, the heating output is 4.0 KW at 230V/50Hz. Casters allow for mobile use, and the feed water consumption is max. 1 liter per batch.
The HV-110L combines a large chamber volume with flexible program control for demanding laboratory environments. For more information on suitable laboratory technology, visit Cooling Technology or Cryotechnology. Request an individual quote now.
Frequently Asked Questions About This Model
What is the HV-110L steam sterilizer used for?
It is used for the steam sterilization of laboratory utensils, media and waste with a chamber volume of 110 liters, for example in microbiology and biotechnology laboratories.
Which technical parameters are decisive for the HV-110L?
The decisive factors are the working temperature of 105°C to 123°C, the maximum chamber pressure of 1.2 bar, and the heating output of 4.0 KW at 230V/50Hz.
For which laboratories is the HV-110L particularly suitable?
Due to its large chamber volume of 110 liters, the device is suitable for laboratories with a high volume of items to be sterilized, for example in research and pharmaceuticals.
What distinguishes the HV-110L from smaller models in the series?
With 110 liters, it has the largest chamber volume in the HV series and is thus designed for larger quantities of items to be sterilized than the models with 25, 50 or 85 liters.
What maintenance or operation is necessary during operation?
The drain valve allows for easy cleaning of the sterilization chamber, the condensate collection container reduces steam and odor nuisance, and the installation site only requires a 230-volt socket.
Technical data & description
Included in base price:
Fully automatic microprocessor control
Timer-controlled night cycle - overnight sterilization keeps the room cool during daytime
AGAR program with afterheat for easier agar processing
Liquid cycle with discharge temperature 95°C
Low feed water consumption, max. 1 liter per cycle
Electronic pressure transducer, pressure and temperature control
Condensate collection container for steam condensation - minimal steam and odor nuisance
Drain valve enables easy cleaning of the sterilization chamber
Manifold connection for discharge lines
Bottom shelf for basket and vessel storage
Casters - floor cleaning possible under the sterilizer
Prepared for printer connection
Prepared for air cooling
Chamber dimensions (mm): 420 Ø x 795 H
External dimensions (mm): 660 W x 1,180 H x 650 D
Operating temperature: 105°C - 123°C
Max. chamber pressure: 1.2 bar
Power rating: 4.0 kW
Voltage: 230V/50Hz
Net weight: 81 kg
2 years manufacturer warranty
-
Beschickungskorb für HV 110 L
Item number: 15762
Ø 390 X 380 mm H
Price on request -
Beschickungskorb mit integrierter Auffang-Schale für HV 110L
Item number: 15767
Ø 390 mm x 380 mm Höhe, aus elektropoliertem rostfreien Edelstahl
Price on request -
Beschickungseimer für HV 110
Item number: 17234
Ø 390 X 375 H
Price on request -
Beschickungseimer für HV 85/110
Item number: 17235
Ø 390 X 375 H
Price on request -
Beschickungseimer mit Deckel für HV 85/110
Item number: 17236
Ø 390 X 375 H
Price on request -
Flexibler Temperaturfühler für HV-Serie
Item number: 15755
zur genauen Sterilisierzeitauslösung über die Medientemperatur
Price on request -
Luftkühlung RL für HV-Serie
Item number: 15756
Price on request -
Einbaudrucker zur Aufzeichnung und Dokumentation
Item number: 15757
von Sterilisiertemperatur- und Zeit, Ausdruck des des gewählten Programms und der Programmparameter
Price on request -
Sterilluft-Filtersystem für HV-Serie
Item number: 15758
Sterilfiltration der Abluft bei infektiösen Materialien
Price on request -
Automatische Wassereinspeisung
Item number: 17225
für HV 25, 50, 85, 110
Price on request -
Filterkerze UF
Item number: 17226
Price on request -
Filterkerze HF Bio X
Item number: 17227
Price on request -
Druckerpapier für Einbaudrucker vor BJ 2002
Item number: 17228
20 Rollen
Price on request -
Druckerpapier für Einbaudrucker
Item number: 17229
20 Rollen
Price on request -
GLP-Paket, bestehend aus Chargendrucker, Abluftfilter mit Inlinesterilisation und Filterelement
Item number: 15764
Price on request -
Hebevorrichtung Loadmaster für HV 85/110
Item number: 17231
Lift mit Schwenkarm, zum Be- und Entladen von Sterilisierkörben bis 30 kg
Price on request -
Prozessdokumentation SegoSoft®
Item number: 17232
für Autoklaven der HG-Serie - Set für die Direktanbindung
Price on request -
Validierungsanschluß
Item number: 17233
Price on request