safety-cabinets approx. 150 cm

Class 2 Safety Cabinets (EN 12469) safety-cabinets approx. 150 cm

Safety cabinets with 150 cm working width offer optimal space for microbiological work with biological agents of risk groups 1 to 3. These Class 2 microbiological safety cabinets according to EN 12469 and DIN 12980 protect personnel, products, and the environment simultaneously through directed airflow and HEPA filtration. They are used in diagnostic laboratories, pharmaceutical companies, biotechnology research facilities, as well as in clinics and pharmacies with microbiological applications.

Class 2 Safety Cabinets (EN 12469) / safety-cabinets approx. 150 cm

Microbiological safety cabinets with 1500 mm working width

Safety cabinets with approx. 150 cm working width belong to Class 2 according to EN 12469 and meet the requirements of DIN 12980 for microbiological safety cabinets. They offer a generous work surface of 1500 mm width and enable comfortable work with biological agents. The units are designed for use in laboratories where personnel, product, and environmental protection must be guaranteed simultaneously. Typical applications include cell culture, diagnostics, microbiology, and pharmaceutical manufacturing.

Standard compliance and certification

The offered safety cabinets comply with the European standards EN 12469 and DIN 12980 for Class 2 microbiological safety cabinets. TÜV certification confirms compliance with safety-related requirements. EN 12469 defines the design, testing, and marking of safety cabinets for protection against biological agents. DIN 12980 specifies requirements for microbiological safety cabinets, particularly regarding airflow, filtration, and protective effect. Regular validation and re-certification are required for safe operation.

Designs and equipment variants

The safety cabinets with 150 cm working width are offered in various equipment variants. Models are available with manually adjustable front windows as well as with electrically adjustable front windows. The electric adjustment allows for comfortable work and precise positioning of the front window for optimal working conditions. The range includes devices from the brands Scanlaf (Mars 1500 Runner) and CleanAir (BioVanguard 5). The working width of 1500 mm offers sufficient space for medium to larger working volumes and multi-part experimental setups.

Areas of application

Microbiological safety cabinets with 150 cm working width are suitable for diverse applications in laboratories of various disciplines. In microbiology, they serve for the safe handling of bacteria, fungi, and viruses. In pharmaceutical companies, they are used for aseptic work, media preparation, and quality control. Diagnostic laboratories use them for sample preparation and cultivation. In biotechnology and research, they are used for cell culture work, genetic engineering, and work with recombinant organisms. Clinical laboratories use them for blood culture diagnostics and resistance testing.

Further working widths for different requirements

In addition to the safety cabinets with approx. 150 cm working width, other size classes are available. Safety cabinets under 100 cm are suitable for smaller laboratories with limited space. Safety cabinets approx. 120 cm offer a compact alternative with sufficient work surface for standard applications. For particularly large working volumes or parallel work by several people, safety cabinets approx. 180 cm are available. The choice of working width depends on the available laboratory space, throughput, and the type of work to be performed.

Accessories and supplementary equipment

Appropriate accessories are available for the operation of safety cabinets. Exhaust systems allow for safe connection to external exhaust air systems and are required for certain applications. Gas burners for microbiological safety cabinets are specially designed for use in air-guided systems and allow for flame sterilization in the workspace. Further accessories can include UV lamps for decontamination, service ports, power strips, and ergonomic armrests. The selection of accessories depends on specific work requirements and safety regulations.

Frequently asked questions about safety cabinets with 150 cm working width

The following answers address central aspects of the selection and operation of microbiological safety cabinets with 1500 mm working width.

For which applications are safety cabinets with 150 cm working width suitable?

Safety cabinets with 150 cm working width are suitable for microbiological work with biological agents of risk groups 1 to 3. Typical areas of application are cell culture, diagnostics, pharmaceutical manufacturing, microbiology, and biotechnological research. The generous work surface allows for comfortable work with several devices and samples simultaneously.

Which working width is suitable for which laboratory requirement?

The choice of working width depends on space, throughput, and the type of work. Safety cabinets under 100 cm are suitable for small laboratories with low space requirements. 120 cm working width offers a compact solution for standard applications. 150 cm working width allows for comfortable work with medium to larger volumes. 180 cm working width is intended for high throughputs or parallel work by several people.

What does the classification according to EN 12469 and DIN 12980 mean?

EN 12469 is the European standard for microbiological safety cabinets and defines design, testing, and marking. Class 2 safety cabinets offer protection for personnel, product, and the environment through directed airflow and HEPA filtration. DIN 12980 defines specific German requirements. TÜV certification confirms the standard-compliant execution and testing of the devices.

What are the differences between manual and electric front windows?

Safety cabinets with manually adjustable front windows are adjusted by hand and offer a cost-effective solution. Electrically adjustable front windows allow for more comfortable work, precise positioning, and can often save programmable working heights. The electric version facilitates frequent position changes and can be coupled with safety functions such as automatic closing.

Which accessories are useful for the operation of safety cabinets?

Exhaust systems allow for connection to external exhaust air systems and are mandatory for certain applications. Gas burners for safety cabinets are specially designed for air-guided systems and allow for flame sterilization. Further useful accessories include UV lamps for decontamination, ergonomic armrests, and special power strips. The selection depends on the application and safety regulations.

How do I receive an offer for a safety cabinet with 150 cm working width?

Offers for safety cabinets with 150 cm working width can be requested via laboratory suppliers and specialist dealers. Relevant information for the request includes: planned application, required risk group, desired equipment (manual or electric front window), space conditions, connection requirements, and, if applicable, GMP or validation requirements. Professional advice helps in selecting the suitable model.

Which validation and maintenance requirements apply to safety cabinets?

Microbiological safety cabinets according to EN 12469 must be validated regularly to ensure protective effect. Initial validation occurs after installation, followed by inspections at least annually or after relocation and filter replacement. Air velocities, airflow, HEPA filter integrity, and protective effect are tested. In GMP-regulated areas, additional qualifications (IQ, OQ, PQ) are required. Regular maintenance includes filter monitoring, UV lamp inspection, and functional tests.