HMT Series - Benchtop Autoclaves

HMC autoclaves HMT Series - Benchtop Autoclaves

HMT Series benchtop autoclaves provide reliable steam sterilisation for laboratories, clinics, pharmacies, and research facilities. These compact units are available with chamber volumes of 16, 24, and 40 litres and operate at 121°C or 135°C. Depending on the model, vacuum, drying, and liquid programmes are available to cover various B2B sterilisation requirements.

HMC autoclaves / HMT Series - Benchtop Autoclaves

HMT Series benchtop autoclaves for professional sterilisation

HMT benchtop autoclaves are designed for use in laboratories, medical facilities, pharmacies, and research labs. They enable the thermal sterilisation of instruments, glassware, textiles, and liquids using pressurised steam. The series includes three chamber volumes: 16 litres (HMT 230), 24 litres (HMT 260), and 40 litres (HMT 300). Their compact benchtop design makes these units suitable for laboratories with limited space without compromising on performance or flexibility.

Operating temperatures and sterilisation cycles

All HMT series benchtop autoclaves operate at either 121°C or 135°C. These temperature ranges meet the requirements for safe steam sterilisation in laboratory and clinical environments. At 121°C, heat-resistant materials are sterilised in standard cycles, while 135°C is used for faster cycles and special applications. The HMT 300MB model also offers an extended temperature range from 105°C to 135°C, providing additional flexibility for temperature-sensitive sterilisation goods.

Vacuum, drying, and liquid programmes

HMT models designated MA and MB (HMT 230MA, HMT 260MA, HMT 300MA, HMT 300MB) feature vacuum and drying functions. The vacuum function improves steam penetration into porous materials and hollow bodies, while the integrated drying process removes residual moisture after the sterilisation cycle. The FA models (HMT 230 FA, HMT 260 FA) are equipped with a liquid programme that allows for controlled cooling, preventing sterilisation liquids in closed vessels from boiling over.

Chamber volumes and areas of application

The 16-litre benchtop autoclaves (HMT 230MA, HMT 230 FA) are suitable for smaller laboratories, medical practices, and pharmacies with low to medium sterilisation requirements. The 24-litre volume (HMT 260MA, HMT 260 FA) offers more capacity for larger batches or longer instruments. The 40-litre units (HMT 300MA, HMT 300MB) cover higher throughput requirements and are used in research labs, diagnostic laboratories, and larger clinics where larger quantities of sterilised goods are processed regularly.

Selecting the right benchtop autoclave

The choice of the appropriate HMT benchtop autoclave depends on the items to be sterilised, the batch size, and the required programmes. For the sterilisation of solids, textiles, and instruments, models with vacuum and drying functions (MA, MB) are advantageous as they ensure thorough air removal and complete drying. Laboratories that regularly sterilise culture media, buffer solutions, or other liquids benefit from the FA models with a liquid programme, as these allow for safe cooling without pressure fluctuations.

Frequently asked questions about HMT benchtop autoclaves

The following answers address typical user questions regarding the HMT series.

For which applications are HMT benchtop autoclaves used?

HMT benchtop autoclaves are used for the steam sterilisation of laboratory instruments, glassware, textiles, culture media, and liquids in laboratories, clinics, pharmacies, and research facilities. They are suitable for both routine sterilisation and special applications with varying temperatures and programmes.

Which chamber volume is suitable for my requirements?

For smaller laboratories and practices with low sterilisation requirements, 16 litres (HMT 230) is sufficient. For medium throughput or longer instruments, 24 litres (HMT 260) is recommended. For larger batches and higher throughput, the 40-litre units (HMT 300) are the right choice.

What is the difference between MA and FA models?

MA models feature vacuum and drying functions and are suitable for solid sterilised goods and porous materials. FA models offer a liquid programme with controlled cooling, specifically developed for the safe sterilisation of liquids in closed vessels.

Which operating temperatures are available?

All HMT benchtop autoclaves operate at 121°C or 135°C. The premium model HMT 300MB additionally offers an extended temperature range from 105°C to 135°C for temperature-sensitive applications.

What accessories are useful for HMT benchtop autoclaves?

Useful accessories include sterilisation baskets, inserts for different container sizes, validation systems for process monitoring, as well as seals and maintenance kits. The choice depends on the sterilised goods and internal quality assurance requirements.

How do I receive a quote for an HMT benchtop autoclave model?

For an individual quote, you can submit an enquiry via the provided contact channels. Please specify the desired model, chamber volume, and any additional requirements to receive a suitable offer.

How is a benchtop autoclave commissioned and validated?

Commissioning includes installation, connection to water and power supplies, and a functional test. For validation, temperature and pressure measurements are carried out to verify compliance with the required sterilisation parameters. Detailed requirements depend on the operator's internal quality standards and regulatory guidelines.